Method for determining angles in x-ray emulsion chambers

Angle detection

Authors

  • S.B. Shaulov P.N. Lebedev Physical Institute of the Russian Academy of Sciences; Moscow Institute of Physics and Technology (State University), MIPT (SU), Moscow, Russia
  • N.O. Saduyev NNLOT, Al-Farabi Kazakh National University, Almaty, Kazakhstan
  • D. Beznosko Bard Early College in New Orleans, New Orleans, LA 70117, USA
  • O.A. Kalikulov Al-Farabi Kazakh National University, Kazakstan, Almaty
  • V.V. Zhukov P.N. Lebedev Physical Institute of the Russian Academy of Sciences, Moscow, Russia
  • V.A. Ryabov P.N. Lebedev Physical Institute of the Russian Academy of Sciences, Moscow, Russia
  • A.L. Shepetov P.N. Lebedev Physical Institute of the Russian Academy of Sciences, Moscow, Russia
  • V.V. Piskal P.N. Lebedev Physical Institute of the Russian Academy of Sciences, Moscow, Russia
  • E.S. Muhkamejanov National Nanolaboratory of Open Type, Al-Farabi KazNU, Almaty, Kazakhstan
  • S.K. Shinbulatov Al-Farabi Kazakh National University, Kazakstan, Almaty
  • A.I. Zhumabayev Al-Farabi Kazakh National University, Kazakstan, Almaty
  • Sh.B. Utey National Nanolaboratory of Open Type, Al-Farabi KazNU, Almaty, Kazakhstan
  • N.O. Yerezhep Al-Farabi Kazakh National University, Kazakstan, Almaty

DOI:

https://doi.org/10.26577/rcph-2019-i2-9

Keywords:

XREC, ADRON, EAS, ionization chambers, cascades, MBS-2 microscope

Abstract

An analysis of the measurement procedure for the zenith and azimuth angles υ and φ in the X-ray emulsion chambers (XREC) of ADRON and PAMIR experiments is presented. Earlier, asymmetry was observed in distributions of azimuth angles of gamma and hadron families. A detailed analysis of methodological errors in measuring θ, φ angles allowed us to establish the causes of the distortion of azimuth angles distributions. There are two reasons: systematic errors in the measurement of zenith angles by MBS-2 microscopes, used both in the PAMIR experiment, and in the ADRON experiment, and the inclination of XREC based on the subsidence. Calculations showed that the total systematic error Δυ≈4 ° completely explains the observed azimuthal asymmetry. Formulas for correcting θ and φ angles are given. The recalculation of the angles by the indicated formulas showed that this corrects the distribution of  the azimuthal angles φ. The REC plane should be set relative to the horizontal with an accuracy of no worse than 1 degree in order to avoid distortion of the angular distributions.

Downloads

Published

2019-06-25